Difference between revisions of "LPDa03ec713.temperature.Calibration"
From Linked Earth Wiki
( CalibrationModel (L) )
(WTLiPD: New page LPDa03ec713.temperature.Calibration with Category: CalibrationModel_(L)) |
(WTLiPD: Edit Page) |
||
Line 1: | Line 1: | ||
− | [[Category:CalibrationModel_(L)]] | + | [[Category:CalibrationModel_(L)]]{{#set:| |
+ | HasUncertainty (L)=LPDa03ec713.temperature.Calibration.Uncertainty| | ||
+ | Notes (L)=ANA2003: Paper uses Mg/Ca=0.34*exp(0.104*SST) and attributes to Anand, but this equation has an exponential constant 0.002 higher than the published value for the G. ruber white 250-350 um Anand et al., (2003) values. Published Anand equation is Mg/Ca=0.34*exp(0.102*SST). Uncertainty is drawn from this latter equation.| | ||
+ | RelevantQuote (L)=10.1029/2002PA000846}} |